A European thermal imaging OEM experienced a critical production halt due to high impedance defects in a micro-coaxial cable assembly used for a beta production series.
- Challenge
- 1,296 out of 2,000 units of AWG#40 CABLINE-VS 1:1 100mm micro-coax assemblies failed due to high impedance, leading to order cancellation, a demand for refunds, and a major trust deficit.
- Solution
- Halted production immediately and conducted joint technical analysis with the customer's engineering team to identify the root cause — a specification definition and testing-method mismatch between the customer's RF lab and our incoming impedance verification. Updated test specifications, provided new test reports, manufactured replacement samples, and processed a full replacement order for the defective units.
- Result
- Successfully resolved the quality complaint, secured a replacement order for all 1,296 defective units, and maintained the long-term partnership despite the severe initial defect rate. The corrected impedance verification procedure has been applied to every micro-coax assembly since.
- AWG #40 conductor
- CABLINE-VS 1:1
- 100mm cable length
- 1,296 of 2,000 units rebuilt
- 0 RMA in subsequent year